Calculation of the Brick Column with Mesh Reinforcement for the Load-bearing Capacity
Objective: Check of the calculation of eccentrically compressed reinforced columns.
Task: It is necessary to verify the correctness of the analysis of stability in the eccentricity plane under eccentric compression and out of the eccentricity plane under axial compression.
References: Reference manual on design of masonry and reinforced masonry structures (supplement to SNiP II-22-81), 1989, p. 33-34.
Initial data file:
Example 8.SAV;
ComeIn 8.doc — report
Initial data:
Mortar
b×h = 0,51×0,64 m | Column dimensions in plan |
l0 = 3 m | Effective column height |
N = 800 kN | Design longitudinal force |
е0 = 5 cm | Force eccentricity |
Stone/brick | Molded clay brick, grade 100 |
Regular cement with mineral plasticizers, grade 75 |
Selection of reinforcement is performed in the example given in the Manual, therefore the results of the selection are used for the verification of KAMIN.
Class of reinforcement Вр-І
Rebar diameter 4 mm
Spacing between meshes 2 masonry courses
Spacing dimensions in plan 3,2×3,2 cm
KAMIN initial data:
Importance factor γn = 1
Age of masonry - up to a year
Working life is 25 years
Stone/brick - Molded clay brick
Stone/brick grade - 100
Mortar - regular cement with mineral plasticizers
Mortar grade - 75
Structure:
Eccentricity of longitudinal force - 50 mm along the Y axis Column height 3 m Longitudinal force 81,549 T Factor for sustained load 1 |
Effective height in the XoY plane |
Effective height in the XoZ plane |
---|---|
Bracing scheme |
Bracing scheme |
Reinforcement:
Rectangular meshes |
Class of reinforcement Bp-I |
Comparison of solutions:
Check |
stability in the eccentricity plane under eccentric compression |
stability out of the eccentricity plane under axial compression |
Theory |
800/828 = 0,966 |
800/1060 = 0,755 |
KAMIN |
0,902 |
0,776 |
Deviation, % |
6,62 |
1,44 |
Comments:
- In order to ensure the value of the percentage of reinforcement μ, equal to the value obtained in the problem (μ = 0,4 %) the spacing dimension in plan is taken as 40 mm.
- Age of masonry and working life have to be specified in KAMIN. Since they are not determined in the problem, the following data are used: "up to a year" and 50 years respectively.
- The column height has to be specified in KAMIN. Since the effective column height determined in the problem is 3 m, this value is used for the column height in the pinned connection model, for which the effective height factor is equal to 1.
- Deviation from the theory of the value of the position stability factor in the eccentricity plane under eccentric compression of 6,62 % is caused by the difference between the characteristic and design reinforcement strength Rsn and Rs. The following values Rsn ∙ γcs = 405 ∙ 0,6 = 243 MPa and Rs ∙ γcs = 365 ∙ 0,6 = 219 MPa in accordance with SNiP 2.03.01-84* are used in the problem; and the following values Rsn ∙ γcs = 490 ∙ 0,6 = 294 MPa and Rs ∙ γcs = 410 ∙ 0,6 = 246 MPa in accordance with the modification No. 2 of SNiP 2.03.01-84* (dated 12.11.1991) are used in KAMIN.