Calculation of the External Load-bearing Wall for Eccentric Compression
Objective: Check of the load-bearing capacity of an external wall.
Task: Check the capacity of masonry for eccentric compression.
References: Nasonov S.B. Manual for Design and Analysis of Building Structures. M: ASV Publishing House, 2013, p. 183-185.
Compliance with the codes: SP 15.13330.2012
Initial data file:
Example 7.SAV
report – ComeIn 7 Nasonov.doc.
Initial data:
lo = 3,0 m | Wall height |
h = 380 mm | Wall width |
b = 1000 mm | Length of a wall section without openings |
N = 350 kN | Design load on the wall |
еo = 0,03 m | Load eccentricity |
Марка кирпича | M150 |
Марка раствора | M50 |
KAMIN initial data:
Importance factor γn = 1
Importance factor (serviceability limit state) = 1
Age of masonry - up to a year
Working life is 25 years
Stone/brick - Molded clay brick
Stone/brick grade - 150
Mortar - regular cement with mineral plasticizers
Mortar grade - 50
Specific weight of masonry 1,8 T/m3
Structure:
|
Clear storey height H = 3 m |
Effective height
Precast floor slabs.
Distance between transverse rigid structures 6 m.
Effective height factor 0,9.
Loads along the wall length
Wind load q = 0 T/m2 |
Comparison of solutions:
Check |
For eccentric compression in the upper section (under the floor slab) |
Source |
350/563,18 = 0,621 |
KAMIN |
0,614 |
Deviation, % |
1,1 % |